Power-Saving Back-UPS ES 8 Outlet 700VA 230V CEE 7/5

APC BE700G-FR uninterruptible power supply (UPS) 0.7 kVA 405 W

Product information

Technical specifications

Weight 6.93 g

Storage relative humidity (H-H) 0 - 95 %
Operating relative humidity (H-H) 0 - 95 %
Storage temperature (T-T) -15 - 40 °C
Operating temperature (T-T) 0 - 40 °C

Hot-swap battery Yes
Battery recharge time 16 h
Battery technology Sealed Lead Acid (VRLA)

Nominal input voltage 230 V
Nominal output voltage 230 V
Dimensions (WxDxH) 224 x 311 x 89 mm
Input connection type French/Belgian
Output connections 8x French/Belgian

Certification CE, GS Mark
Product colour Black
Cable length 1.83 m

Surge energy rating 310 J
Input frequency 50/60 Hz
Output power 405 W
Output power capacity 0.7 kVA

Description

EMI and RFI noise filtering
Reduces line noise that can cause data loss and keyboard errors.

Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance

Data-line Protection
Protection of data lines (Ethernet, Coaxial and Phone lines) ensures complete protection of your equipment from surges. It is very important to protect your equipment from “back door” surges traveling through data lines, as they can be as damaging to your equipment as surges traveling over power lines.

10/100 BaseT Connection
Connect the device to a network using a 10 or 100 BaseT connection
Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require battery back-up while providing surge only protection for less critical equipment

Cold-start capable
Provides temporary battery power when the utility power is out.

Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced

Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Adjustable voltage sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.

Audible alarms
Provides notification of changing utility power and UPS conditions.

User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)

USB connectivity
Provides management of the UPS via a USB port (not available on all models).

Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. UL, FCC, CE, C-Tick approvals.

Adjustable voltage sensitivity
Provides the ability to adapt the Power Conditioner for optimal performance in specific power environments or generator applications.

Battery replacement without tools
Allows quick, easy battery replacement.