Smart-UPS 1500VA LCD 230V

APC Smart-UPS Line-Interactive 8 AC outlet(s)

Product information

Technical specifications

Sustainability certificates RoHS, ENERGY STAR

SmartSlot Yes
USB port Yes
Number of output IEC jumpers 2
AC outlets quantity 8 AC outlet(s)
Power plug C14 coupler
AC outlet types C13 coupler

Weight 24.1 g
Height 219 mm
Depth 439 mm
Width 171 mm

Non-operating altitude 0 - 15000 m
Operating altitude 0 - 3000 m
Storage relative humidity (H-H) 0 - 95 %
Operating relative humidity (H-H) 0 - 95 %
Storage temperature (T-T) -15 - 45 °C
Operating temperature (T-T) 0 - 40 °C

Package weight 27.2 g
Package height 376 mm
Package depth 595 mm
Package width 328 mm
Software CD Yes
Quick installation guide Yes
Cables included RS-232, USB cable

Cold start Yes
Automatic battery test Yes
Hot-swap battery No
Battery recharge time 3 h
Battery life (max) 5 year(s)
Typical backup time at half load 23.1 min
Typical backup time at full load 6.5 min
Battery capacity 408 VAh
Battery technology Sealed Lead Acid (VRLA)

Nominal input voltage 230 V
Nominal output voltage 230 V

Certification CE, CSA, EAC, EN/IEC 62040-1, EN/IEC 62040-2, RCM, UL 1778, VDE, REACH, PEP, EOLI
LED indicators Status
Product colour Black
Cable length 1.83 m
Form factor Tower

Audible alarm modes Low battery alarm, Overload alarm
Audible alarm(s) Yes
Noise level 45 dB
Efficiency 98.7 %
Surge energy rating 459 J
Output operation voltage (max) 240 V
Output operation voltage (min) 220 V
Input frequency 50/60 Hz
Input operation voltage (max) 302 V
Input operation voltage (min) 151 V
Waveform Sine
UPS topology Line-Interactive

Products per pallet 12 pc(s)

Description

Intuitive LCD interface
Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.

Predictive replace battery date
Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.

Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.

Energy meter
Provides actual kilowatt hours of usage for energy conscious users.

Pure sine wave output on battery
Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.

Single switched outlet group
Single outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.

High online efficiency
Reduces utlility costs, generates less heat.

SmartSlot
Customize UPS capabilities with management cards.

Cold-start capable
Provides temporary battery power when the utility power is out.

Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.