APC Smart-UPS Line-Interactive 8 AC outlet(s)
Product information
Technical specifications
Sustainability certificates | RoHS, ENERGY STAR |
SmartSlot | Yes |
USB port | Yes |
Number of output IEC jumpers | 2 |
AC outlets quantity | 8 AC outlet(s) |
Power plug | C14 coupler |
AC outlet types | C13 coupler |
Weight | 24.1 g |
Height | 219 mm |
Depth | 439 mm |
Width | 171 mm |
Non-operating altitude | 0 - 15000 m |
Operating altitude | 0 - 3000 m |
Storage relative humidity (H-H) | 0 - 95 % |
Operating relative humidity (H-H) | 0 - 95 % |
Storage temperature (T-T) | -15 - 45 °C |
Operating temperature (T-T) | 0 - 40 °C |
Package weight | 27.2 g |
Package height | 376 mm |
Package depth | 595 mm |
Package width | 328 mm |
Software CD | Yes |
Quick installation guide | Yes |
Cables included | RS-232, USB cable |
Cold start | Yes |
Automatic battery test | Yes |
Hot-swap battery | No |
Battery recharge time | 3 h |
Battery life (max) | 5 year(s) |
Typical backup time at half load | 23.1 min |
Typical backup time at full load | 6.5 min |
Battery capacity | 408 VAh |
Battery technology | Sealed Lead Acid (VRLA) |
Nominal input voltage | 230 V |
Nominal output voltage | 230 V |
Certification | CE, CSA, EAC, EN/IEC 62040-1, EN/IEC 62040-2, RCM, UL 1778, VDE, REACH, PEP, EOLI |
LED indicators | Status |
Product colour | Black |
Cable length | 1.83 m |
Form factor | Tower |
Audible alarm modes | Low battery alarm, Overload alarm |
Audible alarm(s) | Yes |
Noise level | 45 dB |
Efficiency | 98.7 % |
Surge energy rating | 459 J |
Output operation voltage (max) | 240 V |
Output operation voltage (min) | 220 V |
Input frequency | 50/60 Hz |
Input operation voltage (max) | 302 V |
Input operation voltage (min) | 151 V |
Waveform | Sine |
UPS topology | Line-Interactive |
Products per pallet | 12 pc(s) |
Description
Intuitive LCD interface
Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.
Predictive replace battery date
Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.
Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
Energy meter
Provides actual kilowatt hours of usage for energy conscious users.
Pure sine wave output on battery
Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
Single switched outlet group
Single outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.
High online efficiency
Reduces utlility costs, generates less heat.
SmartSlot
Customize UPS capabilities with management cards.
Cold-start capable
Provides temporary battery power when the utility power is out.
Temperature-compensated battery charging